Informativa cookies

Per offrirti il miglior servizio possibile utilizziamo i cookies e continuando la navigazione ne autorizzi l’uso.

SIGNALLING AND CONTROL

EXTRA LIGHT SERVICE

PVC INSLUATED CABLES FOR LIGHT DUTY, RESISTANT TO FIRE PROPAGATION AND AT LOW HALOGEN ACID GAS EMISSION


Header
Construction features:
Conductor

Flexible bare annealed Cu Cl. 5 or 6 (CEI EN 60228 where applicable)

Insulation

PVC thermoplastic compound R2 quality (CEI 20-11/0-1)

Jacket

PVC thermoplastic compound Rz quality (CEI 20-11/0-1)

Marking

C.E.CAM. ITALY - EXTRA LIGHT SERVICE “sezione” - Eca “ss/aa”

Nominal voltage

300/300 V

Operating temperature

-5°C +70°C

Max short circuit temperature

160°C

Max tensile strenght

15 N/mm2

Min bending radius

8 x Ø est mm

Standards

CEI EN 50525-1 where applicable

European Directives and Regulations

Dir. 2014/35/UE (LVD); Dir 2011/65/UE (RoHS); Dir. Reach; Reg. 305/2011 UE

Reaction to fire

Class Eca (DoP 112)

Application

Small cables for light duty in signalling and panel boards systems

Note

Version with S.Flexstrands also available

C.E.CAM. S.r.l    P.I: 00711830984    Via Fortunato Angelo Morandini, 1 25040 Bienno BS    Tel: +39 0364 306006 - Fax: +39 0364 306007