CCABLES FOR INSTALLATION IN FIXED LAYING FOR THE CONNECTION
OF THE SIGNALS OF AUTOMATED OPENING GATES SYSTEMS
Header
Construction features:
Conductor
Flexible bare annealed Cu Cl. 5 (CEI EN 60228)
Insulation
PVC thermoplastic compound TI 2 quality
(CEI EN 50363-3)
First Jacket
PVC thermoplastic compound TM 2 quality
(CEI EN 50363-4-1)
Second Jacket
Special thermoplastic compound PU based
(CEI EN 50363-10-2 Where Applicable)
Marking
C.E.CAM. SECURITY GATE AUTOMATION “sezione” -
Eca - CE
Nominal voltage
300/300 V fino a sez. 1.0;
450/750 V per sez. 1.5
Operating temperature
-5°C +70°C
Max short circuit temperature
160°C
Max tensile strenght
15 N/mm2
Min bending radius
8 x Ø est mm
Standards
CEI EN 50525-1 where applicable
European Directives and Regulations
Dir. 2014/35/UE (LVD); Dir 2011/65/UE (RoHS);
Dir. Reach; Reg 305/2011 UE
Reaction to fire
Class Eca (DoP 096)
Application
Cable for gates automation, the special Jacket
provides a high mechanical resistance, allowing the
installation in not-protected and damp premises,
especially resistant to mechanical stress.